Runxin Automatic Softening Valves for Efficient and Cost Saving Softening System
Runxin automatic softening valve is the core controller of the water softening system, the general operation process is: running, backwash, brine, slow wash, brine refill, wash.
The Runxin softener control valve, LED or LCD display screen, covers 1-50m3/h water production, It is widely used in homes, companies, factories, schools, troops and other places for water Softening, with strong applicability and practicality.
Runxin Automatic Softener Control Valves Data Sheet
Model | Water Capacity | Running Model | Regeneration Type | Mount Type | Inlet/Outlet | Drain | Brine Tank Connector | Base | Riser Pipe | Available Tank Size | Working Pressure | Water Temperature | Turbidity | Input Charge | Output Charge |
63502 (F65B1) | 2 m3/h | Time Clock | Downflow | Top Mount | 3/4"F | 1/2"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 6"–10" | 0.15–0.6 MPa | 5–45 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
63602 (F65B3) | Meter | ||||||||||||||
63502B (F65G1) | 2 m3/h | Time Clock | Downflow | Top Mount | 3/4"F | 1/2"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 6"–10" | 0.15–0.6 MPa | 5–45 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
63602B (F65G3) | Meter | ||||||||||||||
73502 (F69A1) | 2 m3/h | Time Clock | Upflow | Top Mount | 3/4"F | 1/2"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 6"–10" | 0.15–0.6 MPa | 5–45 °C | < 2 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
73602 (F69A3) | Meter | ||||||||||||||
73502B (F69G1) | 2 m3/h | Time Clock | Upflow | Top Mount | 3/4"F | 1/2"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 6"–10" | 0.15–0.6 MPa | 5–50 °C | < 2 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
73602B (F69G3) | Meter | ||||||||||||||
63503 (F117A1) | 2 m3/h | Time Clock | Downflow | Top Mount | 3/4"F | 3/4"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 6"–10" | 0.15–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
63603 (F117A3) | Meter | ||||||||||||||
63504 (F63C1) | 4 m3/h | Time Clock | Downflow | Top Mount | 1"M | 1/2"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 6"–14" | 0.15–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
63604 (F63C3) | Meter | ||||||||||||||
63504B (F63G1) | 4 m3/h | Time Clock | Downflow | Top Mount | 1"M | 1/2"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 6"–14" | 0.15–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
63604B (F63G3) | Meter | ||||||||||||||
63504C (F63I1) | 4 m3/h | Time Clock | Downflow | Side Mount | 1"M | 1/2"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 6"–14" | 0.15–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
63604C (F63I3) | Meter | ||||||||||||||
63504S (F63B1) | 4 m3/h | Time Clock | Downflow | Top Mount | 1"M | 1/2"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 6"–14" | 0.15–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
63604S (F63B3) | Meter | ||||||||||||||
73504 (F68C1) | 4 m3/h | Time Clock | Upflow | Top Mount | 1"M | 1/2"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 6"–14" | 0.15–0.6 MPa | 5–50 °C | < 2 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
73604 (F68C3) | Meter | ||||||||||||||
73504B (F68G1) | 4 m3/h | Time Clock | Upflow | Top Mount | 1"M | 1/2"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 6"–14" | 0.15–0.6 MPa | 5–50 °C | < 2 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
73604B (F68G3) | Meter | ||||||||||||||
73504S (F68A1) | 4 m3/h | Time Clock | Upflow | Top Mount with handwheel | 1"M | 1/2"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 6"–14" | 0.15–0.6 MPa | 5–50 °C | < 2 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
73604S (F68A3) | Meter | ||||||||||||||
63505 (F116A1) | 4 m3/h | Time Clock | Downflow | Top Mount | 1"M | 3/4"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 6"–14" | 0.15–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
63605 (F116A3) | Meter | ||||||||||||||
63505E (F116E3) | 5 m3/h | Meter | Downflow | Top Mount | 1"M | 3/4"M | 3/8"M | 2.5"-8NPSM | 1.05" O.D. | 10"–20" | 0.15-0.6 MPa | 5-50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
63605E (F130A3) | 5 m3/h | Meter | Downflow | Top Mount | 1"M | NPT 3/4" | 3/8"M | 2.5"-8NPSM | 1"D-GB | 7"–22" | 0.15–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
73505 (F92A1) | 4.7 m3/h | Time Clock | Upflow | Top Mount | 1"M | 3/4"M | 3/8"M | 2.5"-8NPSM | 1"D-GB | 9"–16" | 0.15–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/2.0A |
73605 (F92A3) | Meter | ||||||||||||||
73605E (F92E3) | 5 m3/h | Meter | Upflow | Top Mount | 1"M | NPT 3/4" | 3/8"M | 2.5"-8NPSM | 1"D-GB | 7"–22" | 0.15–0.6 MPa | 5–50 °C | < 2 FTU | AC 100V – 240V / 50–60 Hz | DC 12V/1.5A |
63508 (F133A1) | 8 m3/h | Time Clock | Downflow | Top Mount | 1.5"M | 3/4"M | 1/2"M | 4"-8UN | 1.25"D-GB or 1.66" O.D. | 16"–18" | 0.2–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 24V/1.5A |
63608 (F133A3) | Meter | ||||||||||||||
63510 (N74A1) | 10 m3/h | Time Clock | Downflow | Top Mount | 2"M | 1"M | 1/2"M | 4"-8UN | 1.5"D-GB or 1.9" O.D. | 20"–21" | 0.2–0.6 MPa | 5–45 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 24V/1.5A |
63610 (N74A3) | Meter | ||||||||||||||
63510B (N74B1) | 10 m3/h | Time Clock | Downflow | Top/Side Mount | 2"M | 1"M | 1/2"M | 4"-8UN | 1.5"D-GB or 1.9" O.D. | 20"–21" | 0.2–0.6 MPa | 5–45 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 24V/1.5A |
63610B (N74B3) | Meter | ||||||||||||||
63515 (F99A1) | 15 m3/h | Time Clock | Downflow | Top/Side Mount | 2"M | 1.5"M | 3/4"M | 4"-8UN | 1.5"D-GB or 1.9" O.D. | 30" | 0.2–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 24V/1.5A |
63615 (F99A3) | Meter | ||||||||||||||
73515 (F99D1) | 15 m3/h | Time Clock | Upflow | Top/Side Mount | 2"M | 1.5"M | 3/4"M | 4"-8UN | 1.5"D-GB or 1.9" O.D. | 30" | 0.2–0.6 MPa | 5–50 °C | < 2 FTU | AC 100V – 240V / 50–60 Hz | DC 24V/1.5A |
73615 (F99D3) | Meter | ||||||||||||||
63518 (N77A1) | 18 m3/h | Time Clock | Downflow | Top/Side Mount | 2"M | 1.5"M | 3/4"M | 4"-8UN | 1.5"D-GB or 1.9" O.D. | 30"–36" | 0.2–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 24V/1.5A |
63618 (N77A3) | Meter | ||||||||||||||
63520 (F95A1) | 21.6 m3/h | Time Clock | Downflow | Side Mount | 2"M | 1.5"M | 3/4"M | - | Side mount, top and bottom distributor 2"M | 36"–40" | 0.2–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 24V/1.5A |
63620 (F95A3) | Meter | ||||||||||||||
63520T (F111A1) | 21.1 m3/h | Time Clock | Downflow | Top Mount | 2"M | 1.5"M | 3/4"M | 4"-8UN | 2"D-GB | 36"–40" | 0.2–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 24V/1.5A |
63620T (F111A3) | Meter | ||||||||||||||
73520 (F95D1) | 21.6 m3/h | Time Clock | Upflow | Side Mount | 2"M | 1.5"M | 3/4"M | - | Side mount, top and bottom distributor 2"M | 36"–40" | 0.2–0.6 MPa | 5–50 °C | < 2 FTU | AC 100V – 240V / 50–60 Hz | DC 24V/1.5A |
73620 (F95D3) | Meter | ||||||||||||||
63540B (F112A1) | 40 m3/h | Time Clock | Downflow | Side Mount | DN65 | DN65 | 3/4"M | - | Side mount, top and bottom distributor DN80 | 40"–48" | 0.2–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 24V/4.0A |
63640B (F112A3) | Meter | ||||||||||||||
63550 (F96A1) | 50 m3/h | Time Clock | Downflow | Side Mount | DN80 | DN80 | 3/4"M | - | Side mount, top and bottom distributor DN100 | 60"–63" | 0.2–0.6 MPa | 5–50 °C | < 5 FTU | AC 100V – 240V / 50–60 Hz | DC 24V/4.0A |
63650 (F96A3) | Meter |
Features:
Structure and Performance Features
●LED display, indication of long time power off and data saved after power off (Saved for three days).
●No hard water bypass in rising cycle.
●With signal output connector and two modes (b-01 or b-02) are optional.
●Can set rinsing frequency F-00, realizing one time service and several times of backwashand fast rinse.
●With remote control connector to receive passive signals.
●With interlock connector to realize service simultaneously and rinse one by one.
●Start rising by days or hours.
●N77, F95 and F111 have two valve cores, one is for controlling inlet water, the other is for outlet water.
●Time clock type or meter type is optional.
●N77/F95 with RS-485 port are optional.
Applications
●Residential Softener Systems (F63/F65/F68/F69).
●Softener for RO pretreatment System.
●Boiler Softening System, lon exchange system.
Remark
●The model with a “S" means the valve with manual operation function.
●N77,F95,F111 brine refilled while service, brine refilling controlled by electronic ball valve.
●F63, F65, F68 and F69 have a variety of appearances optional.
●N74B is optional which can be top or side-mounted.